SB2025031412 - Missing Authentication for Critical Function in Siemens SiPass integrated AC5102 and ACC-AP



SB2025031412 - Missing Authentication for Critical Function in Siemens SiPass integrated AC5102 and ACC-AP

Published: March 14, 2025

Security Bulletin ID SB2025031412
Severity
Medium
Patch available
YES
Number of vulnerabilities 1
Exploitation vector Remote access
Highest impact Information disclosure

Breakdown by Severity

Medium 100%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 1 security vulnerability.


1) Missing Authentication for Critical Function (CVE-ID: CVE-2024-52285)

The vulnerability allows a remote attacker to compromise the target system.

The vulnerability exists due to the affected device exposes several MQTT URLs without authentication. A remote attacker can gain access to sensitive information.


Remediation