SB2020061031 - Multiple vulnerabilities in Siemens SIMATIC, SINAMICS, SINEC, SINEMA and SINUMERIK 



SB2020061031 - Multiple vulnerabilities in Siemens SIMATIC, SINAMICS, SINEC, SINEMA and SINUMERIK

Published: June 10, 2020 Updated: June 10, 2020

Security Bulletin ID SB2020061031
Severity
Low
Patch available
YES
Number of vulnerabilities 3
Exploitation vector Local access
Highest impact Code execution

Breakdown by Severity

Low 100%
  • Low
  • Medium
  • High
  • Critical

Description

This security bulletin contains information about 3 secuirty vulnerabilities.


1) Insecure DLL loading (CVE-ID: CVE-2020-7585)

The vulnerability allows a local user to compromise vulnerable system.

The vulnerability exists due to the application loads DLL libraries in an insecure manner. A local user can use a specially crafted .dll file, trick the victim into opening a file, associated with the vulnerable application, and execute arbitrary code on victim's system.


2) Heap-based buffer overflow (CVE-ID: CVE-2020-7586)

The vulnerability allows a local user to perform a denial of service (DoS) attack.

The vulnerability exists due to a boundary error. A local user can pass specially crafted data to the applicatoin, trigger heap-based buffer overflow and cause a denial of service condition on the target system.


3) Unquoted Search Path or Element (CVE-ID: CVE-2020-7580)

The vulnerability allows a local user to execute arbitrary code on the target system. 

The vulnerability exist due to a component within the affected application that regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. A local administrator can execute arbitrary code with SYSTEM level privileges.


Remediation

Install update from vendor's website.