SB2020021212 - Multiple vulnerabilities in Siemens SCALANCE S-600
Published: February 12, 2020
Breakdown by Severity
- Low
- Medium
- High
- Critical
Description
This security bulletin contains information about 3 secuirty vulnerabilities.
1) Cross-site scripting (CVE-ID: CVE-2019-6585)
The disclosed vulnerability allows a remote attacker to perform cross-site scripting (XSS) attacks.
The vulnerability exists due to insufficient sanitization of user-supplied data in the integrated configuration web server. A remote attacker can trick the victim to follow a specially crafted link and execute arbitrary HTML and script code in user's browser in context of vulnerable website.
Successful exploitation of this vulnerability may allow a remote attacker to steal potentially sensitive information, change appearance of the web page, perform phishing and drive-by-download attacks.
2) Resource exhaustion (CVE-ID: CVE-2019-13925)
The vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to uncontrolled resource consumption. A remote attacker can send a specially crafted packets to Port 443/TCP, trigger resource exhaustion and perform a denial of service (DoS) attack.
3) Resource exhaustion (CVE-ID: CVE-2019-13926)
The vulnerability allows a remote attacker to perform a denial of service (DoS) attack.
The vulnerability exists due to uncontrolled resource consumption. A remote attacker can send a specially crafted packets to Port 443/TCP, trigger resource exhaustion and perform a denial of service (DoS) attack.
A cold reboot is required to restore the functionality of the device.
Remediation
Cybersecurity Help is not aware of any official remediation provided by the vendor.